Function
The very high flow Intermech FPA-31-2SS electronic priority fill panel intelligently distributes compressor discharge gas firstly to the trailer, secondly to cascade high bank, thirdly to cascade medium bank and finally to the cascade low bank. This panel features minimum 1” components throughout to provide a flow of up to 10,000Scmh
|
|
Electronic Transmitters
Panel features electronic transmitters to monitor inlet (compressor discharge), cascade banks & trailer pressure.
|
|
Prioritisation Using Electronic Actuators
High flow rate design is achieved by use of 1” air actuated normally closed ball valves - in the event of air failure valves will be shut off by spring.
|
|
Electronic Isolation System
The cascades and trailer can be completely isolated from the dispenser by high flow Electronic Isolation System normally closed actuated ball valves.
|
|
Specifications
• Connections are at least 1” to ensure the panel can be used for VFF of large trailers. • Inlet 1 1/2” NB Sch 160 • Outlet 1” SS • Electric 1 ph 220V to solenoid valve • Air 6mm Line connection • Operating Temp -40oC to 60oC
|
|
Maximum Dimensions
• Depth 0.40m • Width 1.45m • Height 1.45m
|